Can I Use Single Wall Stove Pipe Outside?

by | Last updated on January 24, 2024

, , , ,

Just did some quick research and it turns out that both single- and double-walled stovepipe

are only permitted indoors

. When you transition to the outside through an insulated thimble you must use “Class A Chimney”, which is an insulated product.

Do I need double wall stove pipe outside?

It is always recommended that you use double-wall pipe in a mobile home. The reason why you must use double-wall pipe for a clearance of 18′′ or under is because it is air insulated. The outside of the double-wall pipe

does not radiate heat like

single-wall does.

Where can I use single wall stove pipe?

Use Single Wall Black Stove Pipe from your stove to

a thimble or ceiling transition box

, never inside a combustible wall or inside a chimney chase. An 18 inch clearance to combustibles is required and these pipes feature an unheard of fume-free finish.

Can black stove pipe be outside?


Absolutely not

! Black pipe is not chimney pipe and should only be used up to the point of penetrating the ceiling or wall. … Black pipe used outside will run way cooler flue temperatures than class A chimney and will potentially build up creosote quite rapidly increasing the chance of a chimney fire.

Does chimney pipe have to be double walled?

You have to use

double walled

pipe when going through walls and floors and what not because the double wall and the space between the pipes cools enough that it can come in contact with wall materials. Single walled pipe would get hot enough to ignite the surrounding materials.

Can I use single wall stove pipe in my shop?

Bottom line:

it’s not safe

. Single wall has a CTC (clearance to combustibles) of 18′′. It will also lose integrity over time, much faster than Class A chimney sections. It won’t keep flue gases hot enough to prevent creosote buildup.

Can you pipe a wood stove out the side of your house?

Venting to an Outside Wall

Because a stovepipe or chimney on an outside wall

cannot eliminate

the stack effect, placing your stove there can also result in a cold hearth and a less efficient wood-burning appliance.

Can you use single wall and double wall stove pipe together?


single wall pipe should fit into double wall without an adapter

. … Double wall insulated requires an adapter with a screw-on end to fit the insulated pipe.

What is the clearance for single wall stove pipe?

The NFPA calls for an

18′′

clearance to combustible walls for single wall stove pipe. Double wall stovepipe is used when you don’t have 18′′ or more clearance from combustibles.

Can I vent a wood stove through a wall?

Venting is an important component of all stoves. And wood, gas, and pellet stoves have different venting systems. … For instance, wood-burning stoves will always be vented through the roof of your house, but pellet-burning stoves can be vented vertically through the roof, or

horizontally through the wall

to the outdoors.

Can you put a stove outside?

Yes –

you can put them anywhere in your garden

. Wood burning stoves can be placed on patio or decking outside. … Wood burning stoves are a great addition to any outdoor space. As long as you have the correct fittings and a sound chimney, your stove can be placed anywhere.

Can you use insulation around stove pipe?


You should never have insulation in contact

with a wood stove flue pipe. Most code jurisdictions require the stove pipe be routed through a thimble to provide a safe distance from combustible materials. Air traveling over the surface of the flue pipe may be required to keep it safe and cool.

What direction does stove pipe go?

The male end of the stove pipe for wood burning should

always point down and/or pointing at the stove

. Also, the wood stove pipe should always be inserted into the collar of the wood stove outlet.

How hot does outside of double wall pipe get?

These pipes only need a 2-inch clearance to combustibles because they remain cool on the outside, while their internal design allows them to withstand temperatures as high as

1,700 or 2,100 degrees Fahrenheit

for a limited time.

How hot does triple wall pipe get on the outside?

Double- and triple-wall insulated pipe is listed as Class A vent pipe and must meet either UL standard 103 or 103HT. UL standard 103 requires pipe capable of safety operating with an internal temperature of 1,000 degrees Fahrenheit and withstanding a maximum temperature of

1,700 degrees Fahrenheit

.

Can B Vent be used outside?

Any portion of your B vent system that passes through the occupied area must be enclosed to protect against any emergency, such as the system’s burning. But

we will not recommend installing the B vent pipe on the outside wall

of the building, especially when the outside weather is cold.