What Is The Difference Between A 13 And 13R Sprinkler System?

by | Last updated on January 24, 2024

, , , ,

While NFPA 13 is applicable to a variety of commercial buildings—both residential and nonresidential—NFPA 13R is essentially

only applicable to low-risk residential structures that consist of four stories or less

.

What is the difference between NFPA 13 13D and 13R?

The biggest difference between the three versions of NFPA 13 is

the audience they serve and the allowable omissions within 13D and 13R

. NFPA 13 and 13D focus mainly on life safety and property protection, while NFPA 13R strictly focuses on the life safety aspect.

What is a 13R sprinkler system?

NFPA 13R is a

residential sprinkler design standard focused on low-rise residential occupancies

. The Standard’s intent is to provide a sprinkler system that aids in the control of residential fires and provides improved protection against injury and life loss in multi-family dwellings.

What is the major difference between NFPA 13 and NFPA 13D sprinkler systems?

In other words, NFPA 13R requirements provide for a level of protection that allows occupants to escape a building in the event of a fire. Conversely, NFPA 13

provides protection to not only get people out to safety, but also to control or extinguish the fire

– saving the building and its contents.

What does NFPA 13 mean?

NFPA 13 is

an installation standard

and does not specify which buildings or structures require a sprinkler system. NFPA 13 specifies how to properly design and install a sprinkler system using the proper components and materials after it has been determined that a sprinkler system is required.

How many sprinkler heads can you put on one line?

At different pressures, the sprinkler head and nozzle will consume different amounts of water. For example, at 35 pounds per square inch (PSI) the 5000 Series Rotor using the 3.0 nozzle will use 3.11 gallons per minute (GPM). If your home’s water capacity was 10 GPM, you could place

3 heads per zone

.

Which sprinkler heads are the most common heads for your sprinkler systems?


Pop-up Spray and Rotor Heads

This type of sprinkler head is the most commonly used for residential and small commercial applications. Designed to supply a continuous stream of water, pop-up spray sprinkler heads use a variety of nozzle patterns to distribute the stream of water to suit the contours of your landscape.

When can I use NFPA 13R?

NFPA 13R requires sprinklers in occupied spaces like dwelling units, hallways, and common spaces. It allows

places in residential buildings where fatal fires less

-commonly start to go without sprinklers, like combustible concealed spaces, small bathrooms, and small closets.

When did NFPA 13 come out?


1896

: The first official rules are developed and released governing the installation of fire sprinkler systems. This first set of rules would eventually become NFPA 13: Standard for the Installation of Sprinkler Systems.

Does NFPA 13R require FDC?


A fire department connection (FDC) is required for most

NFPA 13 and 13R automatic sprinkler systems and standpipe systems. … The piping arrangement between the FDC and the sprinkler riser depends on the type of automatic sprinkler system.

Do closets require sprinklers?


Sprinklers are not required in closets

on exterior dwelling unit balconies or breezeways regardless of the size of the closet, provided the closet does not have doors or unprotected penetrations directly into the dwelling unit.

What is the minimum spray density for a residential sprinkler?

Manufacturer’s were successful in obtaining densities as low as

0.03 gpm/sq ft

for residential sprinkler listings.

How many stories are covered in the NFPA 13R Standard?

NFPA 13R – Sprinkler Systems for Residential Occupancies up to and Including

Four Stories

in Height 2007. NFPA 13R is a residential sprinkler design standard focused on low-rise residential occupancies.

What is the latest NFPA 13?

The

2022 edition

of NFPA 13, Standard for the Installation of Sprinkler Systems, is the transformative next step for designers, engineers, contractors, and installers involved with water-based fire protection in today’s world.

What does NFPA 72 stand for?

NFPA 72,

National Fire Alarm and Signaling Code

covers the requirements for installation performance of fire alarm systems. 3. … NFPA 101, Life Safety Code and other codes determine whether occupant notification is required in a given occupancy.

What does NFPA mean?

The

National Fire Protection Association

(NFPA) is a global self-funded nonprofit organization, established in 1896, devoted to eliminating death, injury, property and economic loss due to fire, electrical and related hazards.

David Martineau
Author
David Martineau
David is an interior designer and home improvement expert. With a degree in architecture, David has worked on various renovation projects and has written for several home and garden publications. David's expertise in decorating, renovation, and repair will help you create your dream home.