How Do I Know If My Furnace Control Board Is Bad?

by | Last updated on January 24, 2024

, , , ,
  1. Warning lights. Typically, control boards have LED indicators that function as warning lights. …
  2. Temperature instability. …
  3. Interruptions in the event sequence.

What does the furnace control board do?

The control board runs a series of operations—

starting the electronic ignition, opening the gas valve, checking the burner unit

, activating the blower, shutting off the gas, venting the heat exchanger—that moves the through all the stages of providing you with heat.

How do I reset my HVAC control board?

  1. Shut it Off. First, turn off your AC before resetting the . …
  2. Get to the Circuit Breaker. So far, so good. …
  3. Wait 30 Seconds. After turning off the circuit breaker linked to the AC unit, wait for a full minute. …
  4. Turn it Back On.

What causes a furnace circuit board to burn?

A circuit board can easily incur damage from a number of sources.

Condensation or water dripping onto the unit

can cause the board to burn out. Other damage causes include electrical shorts from dust buildup and an individual touching the board improperly during cleaning.

How do you test a furnace control board?

Common warnings signs that your furnace control board is bad include

warning lights on your furnace's diagnostic system

(see step 1 below), temperature instability (significant fluctuations in temperature, especially when the thermostat is ok) and interruptions in the normal sequencing of your furnace.

How do I reset my central heating system?

  1. First, turn off the power supply to the furnace by turning off the breaker in the circuit box.
  2. Locate the reset button on the furnace and press it to reset the furnace. …
  3. If the button is popped up, press it down.
  4. Return the cover to the blower compartment and turn the power on.

How much is a control board for a furnace?

The average furnace circuit board replacement cost is

$700

. Homeowners can spend $50 on a circuit board, $80 on a furnace inspection, $25 per hour on HVAC technicians, and $500 in total labor costs. Tuning can cost another $120 if the circuit board isn't working properly but doesn't need to be replaced yet.

How long should a furnace circuit board last?

If it is already 15 years old, getting a new circuit board may only add another five years or so to the life of the furnace. On the other hand, investing in a new furnace means you will have

between 15 and 20 years of

life.

Where is control board on furnace?

The circuit board is usually located in

the furnace's blower chamber near the bottom of the unit

. This is where the circulation blower fan motor is mounted.

How do you change a furnace control board?

  1. Ensure that the power to the furnace is off.
  2. Mark all of the wires and write down which connections they go to on the board.
  3. Remove the wires.
  4. Remove the old board (The board may be held in place by screws or plastic clips. …
  5. Attach the new board with the screws or snap it in with the plastic clips.

Why does a circuit board go bad?

Environmental Factors: Exposure to heat, dust and moisture, accidental impact (drops and falls), and power overloads/surges can be causes of circuit board failure. However, the most damaging cause of premature circuit board failure is

electrostatic discharge (ESD) at

the assembly stage.

How do I troubleshoot my central heating system?

Check the thermostat for power and proper settings. Turn on the thermostat and set the temperature so the comes on. If it does not come on, locate the

circuit breaker for

the central heating unit and verify that the breaker is functional. Turn it off and on again, in case it has tripped.

Do all boilers have a reset button?


All boilers have a reset button

but its location and how to use it varies from model to model. … In most cases though, once you've found the reset button you will need to: Push the button and hold (for somewhere between 1-5 seconds) Wait for the boiler to ignite (this could take several minutes)

How do I fix an unresponsive thermostat?

If the thermostat is still unresponsive, make sure

the breaker is shut off and remove the cover

. If it looks dirty inside, use canned air or a soft artist brush to clean away accumulated grime that may be affecting its functionality. Then look for issues like loose wiring or terminal screws and tighten them up.