OSHA’s complete standards for Portable Fire Extinguishers are in regulation 29 CFR 1910.157. Spacing: The potential type of fire dictates the required spacing and distance from employees. For Class A or D fires, travel distance for employees to any extinguisher must be
75 feet or less
.
How much clearance is needed for fire extinguishers?
OSHA requires fire extinguishers to be
at least four inches above the ground
, meaning you cannot store them on the floor.
What is the OSHA standard for fire extinguishers?
A fire extinguisher,
rated not less than 10B
, shall be provided within 50 feet of wherever more than 5 gallons of flammable or combustible liquids or 5 pounds of flammable gas are being used on the jobsite. This requirement does not apply to the integral fuel tanks of motor vehicles.
Can fire extinguishers be blocked?
NFPA 10 Standard for Portable Fire Extinguishers states that fire extinguishers “shall be…. readily accessible and immediately available in the event of fire.” And also that “
Fire extinguishers shall not be obstructed or obscured from view
.”
What is a Coast Guard requirement for fire extinguishers?
The Coast Guard requires boats to have
at least one B-1 marine fire extinguisher
on board. Depending on the size of your boat you may need more than one. Boats less than 26′ have to have at least one B-1 fire extinguisher on board. Boats 26′-40′ need to have at least two B-1 fire extinguishers on board.
Do fire extinguishers need to be mounted?
Fire extinguishers need to be
mounted to the wall
so that they are secure, visible, and readily accessible. It is also important to mount them in such a way that they cannot be easily moved or damaged.
How many fire extinguishers are required per square foot?
(1) A fire extinguisher, rated not less than 2A, shall be provided for each 3,000 square feet of the floor area, or fraction thereof. Where the floor area is less than 3,000 square feet
at least one extinguisher
shall be provided.
Who is responsible for fire extinguishers?
The appropriate person who has had the correct training should
be responsible for using a fire extinguisher on a small fire. You should not use one if you have not been properly trained, unless the fire extinguisher is to be used as an aid to escape.
What signage is required for fire extinguishers?
According to NFPA’s standards, the location of fire extinguishers housed inside cabinets must be
“marked conspicuously
.”[1] Also, in large rooms and in places where visual obstructions exist, “means shall be provided to indicate the extinguisher location.”[2] Local building codes typically follow NFPA standards.
What is required to inspect fire extinguishers?
Examine the extinguisher for obvious physical damage, corrosion, leakage, or clogged nozzle. Confirm the
pressure gauge or
indicator is in the operable range or position, and lift the extinguisher to ensure it is still full. Make sure the operating instructions on the nameplate are legible and facing outward.
What is Fire Class C?
Class C. Class C fires involve
energized electrical equipment
. Extinguishers with a C rating are designed for use with fires involving energized electrical equipment.
How often do fire extinguishers need to be inspected OSHA?
Visual Fire Extinguisher Inspections –
Once per Month
According to OSHA [29 CFR 1910.157(e)(2), employers must perform a visual inspection on portable fire extinguishers at least once per month. This is also a good benchmark for homeowners to follow.
What is the maximum distance between fire extinguishers?
For Class A hazards, each extinguisher must be 2A or larger with a maximum travel distance of
75 feet
between extinguishers. If Class B hazards are present, 10B extinguishers should be positioned so the travel distance for an occupant to reach any extinguisher is 50 feet or less.
Is fire extinguisher required on PWC?
All vessels, including PWC, are required to have a
Type B fire extinguisher
on board if one or more of the following conditions exist: Closed compartments under seats where portable fuel tanks may be stored. Closed storage compartments in which flammable or combustible materials may be stored. Closed living spaces.
How do you tell if a Kidde fire extinguisher is expired?
The model number is printed on the fire extinguisher label. For units produced in 2007 and beyond, the date of manufacture is a
10-digit date code
printed on the side of the cylinder, near the bottom. Digits five through nine represent the day and year of manufacture in DDDYY format.
What happens if you breathe in a fire extinguisher?
Inhalation of monoammonium phosphate and sodium bicarbonate can
cause mild irritation to the nose, throat, and lungs
and results in symptoms like shortness of breath and coughing. Dizziness and headache are also possible. These symptoms usually resolve quickly with fresh air.