Where Installed In Dwelling Unit Kitchens All 125-volt Single Phase 15 And 20-ampere Receptacles That Are Installed Shall Be GFCI Protected?

by | Last updated on January 24, 2024

, , , ,

The 2014 NEC now makes it clear that all 125-volt, single-phase, 15- and 20-ampere receptacles within 6 ft.

of any sink

in a dwelling, including the kitchen sink, must have GFCI protection even if they are under the sink, behind the refrigerator or on an adjacent kitchen wall but not serving the counter.

Which of the following do not require GFCI protection?

GFCI protection is not required for receptacles that are not readily accessible, such as a

ceiling-mounted receptacle for a garage door opener

. Nor are they required for a receptacle on a dedicated branch circuit located and identified for a cord-and-plug-connected appliance, such as a refrigerator or freezer.

Which of the following 125-volt single phase 15 and 20-ampere receptacles are not required to be GFCI protected when installed in dwelling units?

Which of the following 125 volt single phase 15 and 20 ampere receptacles are not required to be gfci protected when installed in dwelling units?

The ground-fault circuit-interrupter protection for personnel

is required for all 125-volt, single-phase, 15- and 20-ampere receptacles installed in boathouses.

Where is a receptacle not required?

GFCI protection is not required for receptacles that are not readily accessible, such as a ceiling-mounted receptacle for

a garage door opener

. Nor are they required for a receptacle on a dedicated branch circuit located and identified for a cord-and-plug-connected appliance, such as a refrigerator or freezer.

What unique type of electrical protection is required for all 120 volt single phase 15 and 20-ampere branch circuits in certain habitable rooms and areas in new dwellings where in the NEC is this requirement found?

All 120-volt, single-phase, 15- and 20-ampere branch circuits supplying dwelling unit kitchens and laundry areas now require

AFCI protection

.

Does a range need to be GFCI protected?


No in any case

. Electric range circuits and receptacles do not require GFI protection, and if this is a regular receptacle for a gas range it is behind the range and not serving the counter, so again ,no GFI required.

How many GFCI protected receptacles are required to be installed outdoors?

210.8(A)(3) Outdoors All 125-volt, single-phase,

15- and 20-ampere receptacles

installed outdoors must be GFCI protected unless meeting the one exception. This requirement is simple and straightforward.

Does every outlet in a kitchen need to be GFCI?


All countertop receptacle outlets must be protected by a GFCI device installed at the outlet

or by GFCI circuit breakers. A kitchen must have two 20-amp circuits for countertop appliances. There should be countertop receptacles installed so that no point along the counter is more than 2 ft. from an outlet.

Is there a difference between GFI and GFCI?

Ground fault circuit interrupters (GFCI) and ground fault interrupters (GFI) are the exact same device under slightly different names. Though

GFCI is more commonly used than GFI

, the terms are interchangeable.

Does dishwasher need GFCI 2020?


Yes, dishwashers!

It’s hard to believe that an appliance that works so closely with electricity and water has not required GFCI protection prior, but the good news is, now it does. Kitchen island receptacle requirements also saw a major overhaul during the 2020 NEC revision cycle.

Can I put a GFCI anywhere in a circuit?


You can replace almost any electrical outlet with a GFCI outlet

. Correctly wired GFCIs will also protect other outlets on the same circuit. … The electrical code also requires GFCIs in unfinished basements, garages, most outdoor receptacles and places where construction activity occurs.

Can you have 2 GFCI outlets on the same circuit?


Yes

, you can use two or more GFCI outlets on the same circuit without any problem at all. The only downside to this is that if one of your GFCI outlets goes down, the others will probably go down as well. … It is well worth putting two or more GFCI outlets on the same circuit, and it’s quite common.

How many receptacles can be on a 20 amp circuit?

Although the National Electric Code (NEC) doesn’t directly rule on limiting outlet installments on your circuit, it is crucial to learn its power draw restrictions. In general, you should have a

maximum of 10 outlets

on a 20A circuit.

What is code for receptacle spacing?

The US National Electrical Code, Section 210.52, states that there should be an electrical outlet in every kitchen, bedroom, living room, family room, and any other room that has dedicated living space. They must be positioned

at least every twelve feet measured along the floor line

.

What is the height of electrical outlets from floor?

The standard height for wall outlet boxes is

about 12 inches

from the top of the floor covering to the bottom of the receptacle box (or 16 inches to the top of the box).

How many outlets can be on a 15 amp circuit?

Technically, you can have as many outlets on a 15 amp circuit breaker as you want. However, a good rule of thumb is 1 outlet per 1.5 amps, up to 80% of the capacity of the circuit breaker. Therefore, we would suggest a

maximum of 8 outlets

for a 15 amp circuit.

Jasmine Sibley
Author
Jasmine Sibley
Jasmine is a DIY enthusiast with a passion for crafting and design. She has written several blog posts on crafting and has been featured in various DIY websites. Jasmine's expertise in sewing, knitting, and woodworking will help you create beautiful and unique projects.