Can 2 GFCI Outlets Share A Neutral?

by | Last updated on January 24, 2024

, , , ,

Can 2 GFCI outlets share a neutral? “

The only way to use two GFCI receptacles to provide GFCI protection to more than two total receptacles on a shared-neutral circuit is to stop sharing the neutral after the GFCIs

– by using two seperate 12/2’s, or 12/2/2.

Contents hide

Do GFCI outlets need their own neutral?


Each GFCI does require a dedicated hot and neutral

, but you can daisy-chain the ground. The way you would normally install two GFCI protected outlets is to put the GFCI closest to the panel, then daisy-chain a regular outlet off of it. If you put another GFCI downstream of a GFCI, it will not work correctly.

Can 2 circuits share a neutral?

What is a multiwire branch circuit?

A multiwire branch circuit is a branch circuit with a shared neutral

. This means there are two or more ungrounded (hot) phase or system conductors with a voltage between them and a shared neutral.

Can you run 2 GFCI outlets together?


Yes, you can daisy chain GFCI outlets together, but it’s unnecessary and provides no added safety

. There’s nothing that says you can’t install multiple GFCIs on the same circuit. However, there is no additional safety gained by doing so.

Does a 2 pole GFCI need a neutral?

Re: 2 Pole GFCI Breaker?

A GFCI does not require a neutral to operate

. it measures the leakage to ground. There may be a neutral wire with the CB in case a multiwire ciruit is used.

Can you wire a GFCI without a neutral wire?


A LINE side neutral connection is ALWAYS required for a GFI breaker

.

Can I run another outlet from a GFCI outlet?


You can replace almost any electrical outlet with a GFCI outlet

. Correctly wired GFCIs will also protect other outlets on the same circuit.

How many circuits can share the same neutral?

One neutral may not have two “hot” wires from the same phase. It is good practice to use

four (4) pole Circuit breakers

(as opposed to the standard three pole) where the fourth pole is the neutral phase, and is hence protected against over current on the neutral conductor.

How do you fix a shared neutral?

Can you tie neutrals together from different circuits?


Tying neutrals of different circuits together is effectively paralleling wire, which unless larger than 1/0 is also a violation of 310.4

. 300.3 references 310.4, tho 300.3 says all conductors of a circuit must be in the same cable, raceway, etc unless allowed elsewhere.

How do you wire two GFCI outlets on the same circuit?

When you need to wire multiple GFCI outlets such as in a kitchen or bathroom you have a couple of options. To save money, you can

put in a single GFCI and then wire additional standard outlets to the “LOAD” output from the single GFCI

. This provides the same protection as having a GFCI at each location.

How many outlets can 1 GFCI protect?

There’s

no limit

. A standard GFCI will protect up to 20 amps, drawn from any combination of receptacles, either the built-in one or any number of additional ones connected to its load terminals.

Is there a difference between GFI and GFCI?

GFCI vs GFI.

Ground fault circuit interrupters (GFCI) and ground fault interrupters (GFI) are the exact same device under slightly different names

. Though GFCI is more commonly used than GFI, the terms are interchangeable.

How does a 220 GFCI breaker work without a neutral?

Wire both hot conductors to the breaker and the breaker pigtail to the neutral bus. There will be no connection to the breaker neutral, so just ignore it. The way the breaker works is

via “vector addition.”

It sums the current of the load and uses that as a reference as the current leaves one leg of the breaker.

Does a GFCI have to have a ground?

In short, yes. If your circuit doesn’t have a ground wire, you can still install a GFCI outlet for protection.

GFCI outlets without a ground wire are legal and work

; however, choosing to install GFCI outlets without a ground wire does come with some disadvantages.

Do I need a neutral wire for 240V?


If a device needs both 120V and 240V, then two ungrounded (hot) conductors and one grounded (neutral) conductor must be used

. If you connect a load between the two ungrounded legs of the circuit, you can see how you have a complete circuit through the coil.

What happens if GFCI is not grounded?

If this “short circuit” occurs and there is no ground wire present,

the current could find its way to ground through other building components in the wall, potentially causing a fire

. Or, if you were to touch the plug at an inopportune time, the current could find its way to ground through your body, causing a shock.

Can you ground a GFCI to the box?


Don’t ground to the electrical box

. Connecting the ground wire to a metal electrical box will energize the box in the event of a short circuit. The box could overheat and start a fire, or someone could get a shock from touching it.

How do I know if my GFCI outlet is grounded?

Test for Absent Ground

Now try

placing one probe of the tester on the screw in the middle of the cover plate and place the other probe into each of the other slots (small and large slots) one at a time to see if the tester lights

. If it doesn’t light for either slot, the receptacle isn’t grounded.

Can I pull power from a GFCI outlet?

In general,

yes

. GFCI outlets have LINE and LOAD terminals. You can connect several more outlets on the LOAD terminals, and they will also be protected from ground faults.

Can a GFCI feed another GFCI?


You can daisy-chain GFCIs if you really want to

. They will still protect just fine. But you have more annoyance dealing with trips… because all the GFCI’s will trip, and you will have to do more walking to find and reset them all.

Can I wire a light switch off a GFCI outlet?


Electrically there is no problem with powering the light with the hot and neutral feed to the GFCI receptacle

. You could use pigtails to the receptacle line (and not use the load connection) and to the light switch so the lights would’t go out if the GFCI receptacle tripped.

What is a shared neutral?

Who are the Shared Neutrals? Shared Neutrals Roster members are

federal employees who mediate as a collateral duty or government retirees who volunteer their services

. They start out as a “co-mediator,” trained in basic mediation skills but with limited experience.

Can dedicated circuits share a neutral?

A dedicated vs separate circuit is the argument– As I seeit

a dedicated circuit should not share a neutral

and a separate circuit may share it.

Can you put 2 neutral wires together in a breaker box?


Neutrals must be one to a hole

. No exceptions. NEC 2011: 408.41 Grounded Conductor Terminations Each grounded conductor shall terminate within the panelboard in an individual terminal that is not also used for another conductor.

What does a borrowed neutral mean?

A borrowed neutral is

when you have two seperate circuits but you have taken the neutral from one circuit to supply the other with a neutral

.

Why do I have 2 neutral wires?

Two cables are neutral and do the same. If you are re-wiring the outlet yourself this can be confusing, but it is not unusual or wrong to have more than one set of black and white wires in your outlet box.

Each wire serves a purpose and understanding each one will give you confidence when working inside an outlet

.

Does NEC allow shared neutrals?

Sharing neutral or yoke


The NEC does not define multiple circuits

. However, relating to 210.7, it appears to mean more than one circuit, on separate phases and each with its own neutral. If the circuits were on the same phase, simultaneous disconnection in the panelboard would not be possible.

Can you daisy chain neutral wires?

Can I pigtail a neutral wire?

When making a pigtail, choose a scrap of wire with insulation that is the same color as the circuit wires you are connecting:

white pigtails when connecting to neutral wires

, red or black when connecting to hot wires, green or bare copper when connecting to grounding wires.

Can you put 5 neutral wires together?

You can’t just take one of the neutral wires from the bundle and use it because you have no idea if it goes to the breaker box or if it goes on down the line to a light or outlet.

If the 5 wires are bound together, the only thing you can do is add a sixth wire

.

Does every outlet in a kitchen need to be GFCI?

Does GFCI have to be first in line?

Re: Does GFCI Have to Be First In Line?

Yep, GFCI first receptacle outside

, and feed others from that. You ‘should’ not have more than 1 GFCI on a circuit, although it would still work, it would be a waste of a GFCI !

How many outlets can be on a 15 amp circuit?

Technically, you can have as many outlets on a 15 amp circuit breaker as you want. However, a good rule of thumb is 1 outlet per 1.5 amps, up to 80% of the capacity of the circuit breaker. Therefore, we would suggest a

maximum of 8 outlets

for a 15 amp circuit.

Should a refrigerator be plugged into a GFCI outlet?

Residential Kitchen

In a dwelling unit (residential), GFCI protection is only required for kitchen receptacles that serve the countertop surfaces.

There’s no requirement to GFCI protect receptacles that serve a refrigerator

. Unless the fridge is plugged into a countertop receptacle.

How many outlets can a 20 amp GFCI protect?

The answer to the question how many outlets on a 20 amp circuit is

ten outlets

. Always comply with the 80% circuit and breaker load rule, allowing a maximum load of 1.5 amps per receptacle. Remember that your circuit, wire sizes, and outlets must be compatible to avoid overheating and electrical hazards.

David Martineau
Author
David Martineau
David is an interior designer and home improvement expert. With a degree in architecture, David has worked on various renovation projects and has written for several home and garden publications. David's expertise in decorating, renovation, and repair will help you create your dream home.