What Fire Exit Signs Do I Need?

by | Last updated on January 24, 2024

, , , ,

What fire exit signs do I need? Exits must be clearly designated by

a large sign that is free of obstructions and/or decorations

. If there are doors along an exit route that could be mistaken for the actual exit, those doors must be clearly marked so that no one could mistake them for the exit.

Do I need illuminated exit signs?

Section 29 CFR 1910.37(q)(6),

requires that exit signs in occupied workplaces be illuminated from a reliable external light source which provides a minimum of 5-foot candles on the sign surface

. Electrical power supply from a public utility company is considered to be reliable.

Where are exit signs required NFPA?

NFPA 101 also requires egress signage to be provided in most occupancies—including, but not limited to, assembly, educational, hotels, mercantile, and business—

on exits other than main exterior doors that are not obvious and identifiable as exits

.

What are the two types of exit signs?

  • Thermoplastic LED Exit Signs. The most common type of exit sign is made of economical thermoplastic and is illuminated with LEDs. …
  • Edgelit Exit Signs. …
  • Photoluminescent Exit Signs.

What is the electrical code for exit signs?


Exit Signs for doors and corridors should be mounted with the bottom of the exit no more than 80 inches (6’8′′) above the top edge of the egress opening

. Floor proximity exit signs require the bottom of the sign be mounted no less than 6′′ from the floor and no more than 18′′ above the floor.

Should exit signs be red or green?

In the United States,

exit signs can have either red or green lettering, but traditionally have been red

. Many states or cities have enacted building codes which specify the sign color.

Does OSHA require exit signs?

The Occupational Safety and Health Administration (OSHA) standard at 29 CFR [1910.37(b)(7)]

requires exit signs to be [not less than six inches (15.2 cm) high, with the principal strokes of the letters in the word “Exit” not less than three-fourths of an inch (1.9 cm) wide]

.

What is the difference between NFPA 1 and NFPA 101?


NFPA 1: Fire Code is adopted and enforceable in 19 states. Every state uses portions or an edition of NFPA 101: Life Safety Code, and it has been fully adopted by 43 states

. In contrast, the NFPA’s competing document to the IBC—NFPA 5000: Building Construction and Safety Code—is only used by reference in 7 states.

Do exit signs have to be hardwired?


Power-free or “wireless” Exit Signs do not need to be hard-wired to a building’s electricity

. Instead they receive their illumination from other energy sources. Photoluminescent Exit Signs, for example, are illuminated via the action of photoluminescence.

Do exit signs have to have battery backup?

The IBC (International Building Code), an organization that codifies safety standards, states in section 1011.5. 3 that

an exit sign must stay illuminated at least 90 minutes during a situation of main power loss

. Batteries afford this security, but it is limited to short durations of time.

What color do exit signs need to be?

Q: Is there a requirement for exit sign color? Some facilities have green, other facilities have red. A: There is no OSHA requirement for specific colors; however, OSHA states it must be

distinctive in color from the background

. NFPA 101 Section 7.10.

Do exit signs need arrows?


Exit signs with arrows need to be posted along the exit routes in order to indicate the direction of travel to the nearest exit when it is not apparent

. Exit signs with arrows can have directions pointing left, right, up, or down.

Why are exit signs green now?

Color psychology

We are trained to recognize red as ‘stop’, so in an emergency situation it might create confusion. Whereas

green color is related to safety and ‘go’

, clearly instructing the public to remain calm and follow the signs. This is why public buildings have green emergency signs.

Are photoluminescent exit signs OSHA compliant?

Based upon this policy, we determined that

your self-luminous and electroluminescent exit sign products will meet OSHA requirements if installed and maintained in a manner recommended by your company

.

What is the standard size of fire exit signage?

Fire Exit Sign Board

Dimension:

12′′ x 6′′,18′′ x 6′′

(Available) Shape: Rectangular. Film Type: Reflective.

What height should fire exit signs be?

In terms of mounting, the general requirements are that: signs mounted above doors should be at a height of

between 2.0m and 2.5m above the floor

. signs on walls should be mounted between 1.7m and 2.0m above the floor.

Do all exit signs need to be red?


Any color, or color combinations, that is readily visible or distinctive in appearance on exit signs is acceptable to OSHA

. It is possible that local building codes may requires a certain color, but our standards do not.

Can emergency exit signs be blue?


Signs indicating mandatory requirements consist of a blue circle with the pictogram or text in white positioned centrally

. These signs should be used to indicate escape routes, emergency exits, first aid equipment, emergency showers and the like.

What is the difference between fire exit and emergency exit?


While the purpose of fire doors is to stop the spread of fire inside the building, fire exit doors are designed to provide a quick and safe exit from the building

. Some basic requirements apply to emergency exit doors for commercial buildings, public buildings, and other workplaces.

What does OSHA require for fire exits?

Ceilings of exit routes must be at least 7 feet, 6 inches high. An exit access must be at least 28 inches wide at all points. Where there is only one exit access leading to an exit or exit discharge, the width of the exit and exit discharge must be at least equal to the width of the exit access.

How many fire exits are required by law?

The fire exit regulations recommend that there are at least two escape routes from every part of premises that are completely independent of each other.

Are NFPA codes mandatory?


In most cases, compliance with NFPA standards is voluntary

. However, in some cases, federal or state Occupational Safety and Health (OSHA) agencies have incorporated wording from NFPA standards into regulations. In these cases, complying with the standards is mandatory.

What does NFPA 101 apply to?

Relevant to life safety in both new and existing structures, NFPA 101 covers

everything from means of egress and features of fire protection to hazardous materials emergencies, injuries from falls, and emergency communications

.

What is the half diagonal rule?

For new structures, there is something called the “one half diagonal rule”. This means that

the means of egress must be located no less than half of the diagonal distance of the area being serviced

.

How long do exit signs last?

“Electrical (LED) exit signs have a service life of

5-10 years

; Radioluminescent (tritium) exit signs last for 10, 15 or 20 years; Photoluminescent exit signs have an unlimited service life and consume no energy.”

Do emergency lights have to be on their own circuit?

If you are in the US (National Electrical Code territory)

the emergency lighting units should be fed by the same circuit as the lighting

, but it must of course be ahead of any switching.

Do emergency lights have to be on all the time?

Should emergency lighting be on all the time? Emergency lighting should always be connected to its power source, but

it does not need to be always illuminated

.

How long does an emergency light battery last?

How long does emergency lighting last? A fully charged battery in good condition should power an emergency light for

at least 90 minutes

as mandated by UL (Underwriters Laboratories). If the battery cannot last for 90 minutes, it must be replaced.

How do transparent exit signs work?

Self luminous tritium exit signs are

illuminated via the radioluminescence of the phosphor coating of a glass tube by electrons emitted from a tritium gas

. Basically the electrons of the phosphor coating are excited into emitting electromagnetic radiation in the visible spectrum (i.e. light).

What Colours are fire exits signs?

Most international building codes prescribe green as the color for exit signs. However, certain codes, such as the National Fire Protection Association (NFPA) 101 let users choose between

red and green

exit signs.

What colour should a fire exit be?

Fire exit doors should have

green

signage indicating an exit. Fire exit signs are green because this has become the universal colour for “go”. Every fire exit sign should be suitably illuminated via a reliable source of light and if not, should light up.

Why are fire exits green?

Green is commonly understood as the ‘colour of safety. ‘

The rods in the human eye are more sensitive to green light

, so these signs are easier to see in dark conditions.

How should exit signs be displayed?


The sign must consist of plain, legible letters and be a distinctive color that stands out from the background

. All exit route doors must lack furnishings, decorations, or equipment that obscure the exit or the exit sign. The line-of-sight to an exit sign must be unobstructed at all times.

How many emergency lights do I need?

2. Non-Maintained Lights, which are never on unless there is a power failure and then will light for 3 hours. The requirement then in broad terms is to provide

a minimum of 1 Lux illumination along all the escape routes

.

Can exit lights be green?

Although

exit signs with red or green lettering are generally acceptable

, some states have adopted specific preferences for the color of exit signs. If you’re unsure who to reach out to regarding local emergency exit requirements, the fire marshal or inspector is a good starting point.

When did exit signs become mandatory?

First, a brief history of exit signs is needed in order to understand how they have evolved and where we are at today. In the United States, it all started in

1911

.

Emily Lee
Author
Emily Lee
Emily Lee is a freelance writer and artist based in New York City. She’s an accomplished writer with a deep passion for the arts, and brings a unique perspective to the world of entertainment. Emily has written about art, entertainment, and pop culture.