What Is Differential Scanning Calorimetry Used For?

by | Last updated on January 24, 2024

, , , ,

DSC is a thermodynamical tool for direct assessment of the heat energy uptake , which occurs in a sample within a regulated increase or decrease in temperature. The calorimetry is particularly applied to monitor the changes of phase transitions.

What is differential scanning calorimetry analysis?

Differential Scanning Calorimetry (DSC) is a thermal analysis technique in which the heat flow into or out of a sample is measured as a function of temperature or time , while the sample is exposed to a controlled temperature program.

Why do we use differential scanning calorimetry?

Differential scanning calorimetry can be used to measure a number of characteristic properties of a sample . Using this technique it is possible to observe fusion and crystallization events as well as glass transition temperatures T g . DSC can also be used to study oxidation, as well as other chemical reactions.

What is DSC and how it works?

Differential Scanning Calorimetry (DSC) is primarily used to characterise the stability of biomolecules like proteins . ... By heating the molecule at a constant rate, measurement is made of the change in heat associated with thermal denaturation of the biomolecule.

What information do you get from a differential scanning calorimetry plot?

You plot the difference in heat flow as a function of temperature . MELTING: The melting of a solid is endothermic. The extra heat flow to maintain the temperature shows up as a peak on the DSC plot.

What is difference between DTA and DSC?

Differential thermal analysis (DTA) is suited for the determination of characteristic temperatures, while differential scanning calorimetry (DSC) additionally allows for the determination of caloric values such as the heat of fusion or heat of crystallisation.

What is TGA principle?

The principle of TGA and its applications: TGA is thermogravimetric analysis . It is one of the thermal method of analysis. ( Thermal methods of analysis are based on the dynamic. relationship between temperature with a change in physical property like mass change or enthalpy change. etc)

What is TGA?

Glass Transition Temperature | Tg

The glass transition temperature (Tg) is somewhat of a misnomer, as it is actually a range of a few degrees Celsius over which a polymeric material transitions from a glassy (rigid) to elastomeric (rubbery) state. ... The Tg of a material helps to define its mechanical properties.

What is DTA curve?

The DTA curve is a curve of temperature difference between the sample material and the reference material versus temperature or time . Applications of DTA include: • DTA is widely used in the pharmaceutical and food industries.

What are the principles of DSC?

DSC enables the measurements of the transition such as the glass transition, melting, and crystallization . Furthermore, the chemical reaction such as thermal curing, heat history, specific heat capacity, and purity analysis are also measurable.

What can a DSC measure?

DSC is a thermal analysis apparatus measuring how physical properties of a sample change, along with temperature against time . In other words, the device is a thermal analysis instrument that determines the temperature and heat flow associated with material transitions as a function of time and temperature.

What are the different types of DSC?

  • Principles of DSCs. ...
  • Heat Flow DSC. ...
  • Heat Flux DSC. ...
  • High-Pressure DSC (HP-DSC) ...
  • Ultra-Violet DSC (UV-DSC) ...
  • Fast Scan DSC. ...
  • Modulated Temperature DSC (MT-DSC) ...
  • DSC with Other Techniques.

What is difference between DSC and TGA?

TGA DSC Typical Output · % by mass lost or gained · residual mass · Transition temperature (e.g. onset, peak) · Transition enthalpy

How does DSC measure Tg?

Simply stated, DSC utilizes a heat flow technique and compares the amount of heat supplied to the test sample and a similarly heated “reference” to determine transition points. Tg is typically calculated by using a half-height technique in the transition region .

What are the factors affecting the differential scanning microscopy curve?

Factors affecting DSC curve

Instrumental factors: These include parameters such as – Furnace heating rate, furnace atmosphere, recording speed, geometry of sample holders, location of sensors, sensitivity of the recording system and material of the sample container .