What Is The Correct Ground Fault Circuit Interrupter GFCI Level For A Class A Device?

by | Last updated on January 24, 2024

, , , ,

There is a Class A GFCI that trips when a ground fault current

exceeds 5 milliamps

and there is a Class B GFCI that trips when a ground fault current exceeds 20 milliamps.

What is a Class A GFCI receptacle?

Ground Fault Circuit Interrupter, Class A (Class A GFCI) – a ground

fault circuit interrupter that will interrupt the circuit to the load

, within a predetermined time, when the ground fault current is 6 mA or more but not when the ground fault current is 4 mA or less (see Appendix B).

What is the correct GFCI level for a Class A device?

It states that a Class A GFCI trips when the current to ground has a value in the range of

4 milliamps to 6 milliamps

, and references UL 943, the Standard for Safety for Ground- Fault Circuit-Interrupters.

What class of GFCI is most common?

The two most common types of GFCI’s used in the entertainment industry are

Class A and Class C

.

At what value does a Class A ground fault circuit interrupter trip?

Class “A” GFCI devices are the most common.

Trip when current to ground is

6 milliamperes (6/1000 of an ampere) or greater

.

How many milliamps does it take to trip a GFCI?

It takes only

5 mA (0.005 A)

of current leakage from the hot wire to the ground to cause a GFCI to trip. A small amount of leakage current may be difficult to avoid in some normal circuits.

Will a GFCI trip on overcurrent?

So a GFCI receptacle outlet does not trip due to an overloaded circuit. …

A GFCI breaker in a panel will trip

, however, because it combines both overcurrent and GFCI protection in one device—and the overcurrent protection part will cause it to trip.

What does GFCI stand for?

The

ground-fault circuit interrupter

, or GFCI, is a fast-acting circuit breaker designed to shut off electric power in the event of a ground-fault within as little as 1/40 of a second. It works by comparing the amount of current going to and returning from equipment along the circuit conductors.

At what level of fault current are GFCI receptacles required to trip by law?

This value must be less than the current level required to operate the overcurrent protective device of the circuit. Where the GFCI is required to provide protection for personnel, the level must be

above 4 milliamperes but not more than 6 milliamperes

and must operate within a time-frame of less than 25 milliseconds.

Where does the code require GFCI protection for certain kitchen receptacles?

Kitchens: All

receptacles serving countertop areas and any receptacle within 6 feet of a sink

must have GFCI protection. Also, the receptacle supplying a dishwasher should be GFCI-protected.

Is there a difference between GFI and GFCI?

Ground fault circuit interrupters (GFCI) and ground fault interrupters (GFI) are the exact same device under slightly different names. Though

GFCI is more commonly used than GFI

, the terms are interchangeable.

What causes nuisance tripping of GFCI?

“Nuisance Tripping” can trip you up!


Excessive lengths of temporary wiring or long extension cords can cause ground fault leakage current to flow by captive and inductive coupling

. The combined leakage current can exceed 5 ma, causing the GFCI to trip.

Will a GFCI trip before a breaker?

They’ll both trip


When you go to reset the receptacle

, it will be dead. You will need to go down to the basement to reset the GFCI breaker, and then, the GFCI outlet will have a chance of being reset.

What does breaker trip mean?

A circuit breaker “trips” (

shuts off the electrical flow

) in order to protect the circuit from overheating. It’s a safeguard that helps prevent damage and electrical fires.

What level of ground fault current is considered in electronic detection for equipment protection?

Ground fault interrupters designed to provide life protection must open a circuit at 5 milliamps (± 1 milliamp). Ground fault protection for equipment must open a circuit when ground fault current reaches

30 milliamps

.

How many conductors can be on a GFCI breaker?

Three-pole (three-phase) GFCI circuit breakers are only suitable for protection of a three-phase load; hence, only the

three

-phase conductors must pass through the CT. The white “pigtail” wire on a GFCI circuit breaker serves two functions.

Carlos Perez
Author
Carlos Perez
Carlos Perez is an education expert and teacher with over 20 years of experience working with youth. He holds a degree in education and has taught in both public and private schools, as well as in community-based organizations. Carlos is passionate about empowering young people and helping them reach their full potential through education and mentorship.