But looking at the title of this thread, are you referring the difference between #1 AWG and 1/O AWG? There is a difference,

1/O is one wire size larger

.

How many amps can 1 0 AWG wire handle?

Wire Size 75°C (167°F) AWG (mm2) Copper 1 (42.4) 130 1/0 (53.5)

150
2/0 (67.4) 175

What is bigger 1 0 AWG or 2 0 AWG?


1/0 is 0 AWG

, 2/0 is 00 AWG, 3/0 is 000 AWG and so on with more zeros being thicker wire. … Pure aluminum wire is equivalent in current carrying capacity of a copper wire two gauges smaller, so pure aluminum 1/0 wire is equivalent to 2 AWG copper wire…

What size wire is 1 0 AWG?

AWG Diameter Area 0000 (4/0) 0.4600 107 000 (3/0) 0.4096 85.0 00 (2/0) 0.3648 67.4 0 (1/0)

0.3249

53.5

Is higher AWG better?

In general,

a lower AWG number is better than higher AWG

. … Since these electrical signals are usually low power, smaller AWG (larger wire) is not needed. In these situations, proper shielding and cable-pair twisting is more important for signal integrity than the AWG of the strands.

What size wire do I need for 200 amp service?

Wiring 200 amp service requires either

#2/0 copper wiring or #4/0 aluminum or aluminum clad wiring

. Which wire used is determined by the voltage drop and length of the wiring. Many electrical contractors opt to use #4/0 aluminum or copper-clad wire.

What size wire do I need for 100 amp service?

The cable must have a wire gauge sufficient to the amperage of the subpanel—a 100-amp subpanel requires

#4 copper wires or, more commonly, #2 aluminum wires

, for example. (Aluminum is often used for feeder cables because the cost is typically much lower than that of copper wires.)

How many amps will a 2 0 wire carry?

3-Wire residential services, allowable ampacities Copper AWG Aluminum AWG Service Ampacity 3 1 110 2 1/0

125
1 2/0 150

What wire size do I need to go 100 feet for a 60 amp service to a workshop?

If the circuit is 100 amp or less you have to size the conductors based on the 60-degree celsius column unless the breaker and the equipment terminations are rated for 75 or 90 degrees. You have to use

a #4 conductor

to feed a 60 amp circuit.

What size of wire do I need for a 60 amp breaker?

For 60 ampere breakers, electricians and professionals suggest using a wire size gauge

ranging from 6 AWG to 4 AWG

. All household wires have a rating of at least 600V, so only amperage really matters when it comes to determining wire gauge.

What is 10 AWG wire?

American Wire Gauge (#AWG) Diameter (inches) Diameter (mm) 9 0.114 2.91 10

0.102


2.59
11 0.0907 2.30 12 0.0808 2.05

What is 24 AWG wire used for?

24AWG cable is the most versatile out of these because it will be constructed with more copper making

it better for longer distances

. You also won’t encounter as much cross talk or insertion loss at longer distances with this cable. 26AWG cables are a great choice for shorter runs and making patch cables out of it.

What does 12 AWG wire mean?

AWG stands for

American Wire Gauge

. This numbering scheme was established way back in 1857, and today, remains the standard in North America that specifies the cross-sectional area of a conductor, and therefore its current carrying capability. … 12 AWG, or 12 ga. They all mean the same thing and are used interchangeably.

What happens if wire gauge is too big?

using larger wire will not hurt anything or cause any overload.

The larger wire will cost more, the pathway or where it has to fit, and the physical size of the connecting means

(ie. the size of terminal or clamp it has to fit in), will all be determining factors in just how big is too big.

How is AWG calculated?

AWG: In the American Wire Gauge (AWG) system, wire size diameters can be calculated by applying the

formula D(AWG)=. 005·92

(( 36 – AWG )/ 39 )

inch

. For the 00, 000, 0000 etc. … 460 * (0.890625)

( awg + 3 )

.

What is 18 AWG wire used for?

18-gauge are used for

low-voltage lighting and lamp cords in 10 amps

. 16-gauge are used for light-duty extension cords supporting 13 amps. 14-gauge are usedfor light fixtures, lamps, lighting circuits with 15 amps.