OSHA requires that fall protection be provided at elevations of four feet in general industry workplaces, five feet in shipyards, six feet in the construction industry and eight feet in longshoring operations.

What is the code for fall protection in construction?

Workers engaged in residential construction 6 feet or more above lower levels must be protected by conventional fall protection (i.e., guardrail systems, safety net systems, or personal fall arrest systems) unless another provision in 29 CFR 1926.501 (b) provides for an alternative fall protection measure.

What are the requirements that a fall protection plan must meet?

  • State information about the job site. ...
  • Assess the fall hazards on site. ...
  • Outline the fall arrest or restraint methods and fall protection equipment being used. ...
  • Outline the assembly, maintenance, inspection, and disassembly procedures for equipment being used.

What are the 4 methods of fall protection?

Categories of Fall Protection

All active fall protection for the construction industry falls into four basic categories: fall arrest, positioning, suspension, and retrieval . OSHA provides standards for each category of fall protection.

What are the primary principles of fall protection?

An individual’s own body and balance, the ability to stand, walk, and not fall is typically the primary layer of protection. If the primary fails (e.g. due to a trip, slip, etc.) the guardrails, the secondary layer of protection, would prevent a fall to a lower level.

What item is an example of fall protection?

Scaffolds, handrails, barriers and movable platforms can be constructed to protect workers employed at heights. Where these devices are impractical, personal fall protection equipment such as full body harnesses, lanyards and retractable lifelines may be used.

At what height is fall protection required on scaffolds?

The standard requires employers to protect each employee on a scaffold more than 10 feet (3.1 m) above a lower level from falling to that lower level.

What are the 2 types of fall protection?

There are two major types of fall arrest: general (nets) and personal (lifelines) .

What is the fall protection standard?

For general industry, OSHA requires fall protection beginning at a height of four feet . In construction, fall protection is required above six feet. Protection must also be provided any time an employee must work above hazardous equipment or machinery, regardless of the distance.

What is the most common fall protection?

On many sites, guardrails are the most common and convenient means of fall protection. Where guardrails cannot be used, workers must use another means of fall protection to prevent a fall. Two basic types of fall protection are travel restraint and fall arrest. Both involve wearing a full-body harness.

What are the two major types of fall protection harness buckles?

Modern fall protection harnesses feature different leg fasteners. You can choose from among pass-through buckle, tongue buckle, and quick-connect buckle .

Which is the best fall control OSHA?

1. Hazard Elimination . The preferred solution to all fall hazards is elimination. The reason for exposure to the fall hazard is challenged and evaluated to determine if a change in the procedure, practice, location or equipment will eliminate exposure to the fall hazard.

Who is responsible for fall protection?

2) “Who is responsible for providing fall protection?” The employer is ultimately responsible for safeguarding employees against falls and creating a safe environment for workers and visitors.

What is clearance distance in fall protection?

The total fall clearance distance is the minimum vertical distance between the worker and the lower level that is necessary to ensure the worker does not contact a lower level during a fall .

What is a yoyo in fall protection?

Yo-yos are a type of lanyard that allow the user to freely move around the workspace as the lifeline cable extends out of the housing and, in turn, coils back up inside the shell as the worker gets closer to the unit again to keep the cable taut.

Is fall protection required on a ladder?

Fixed ladders: fall protection must be provided for employees climbing or working on fixed ladders above 24 feet . 29 CFR 1926.1053(a)(19) states that fall protection must be provided whenever the length of climb on a fixed ladder equals or exceeds 24 feet.