Why Is My Goodman Furnace Short Cycling?

by | Last updated on January 24, 2024

, , , ,

A dirty air filter is the most common cause of short-cycling . If your air filter is clogged with dirt, it won't allow proper air flow to the heat exchanger. That can cause the to overheat and forces the high limit switch to ride to the rescue by shutting the furnace off.

Can thermostat cause short cycling?

Your could also cause the HVAC system to cycle on and off rapidly , a process known as short cycling. Your furnace or central air conditioner spends a good amount of energy simply turning on and off, which is why you want yours to run for at least 15 minutes at a time before shutting off.

What can cause a gas furnace to short cycle?

  • It's overheating.
  • Having a bad flame sensor.
  • Your furnace filter is dirty.
  • Blocked heat grates.
  • Blocked exhaust vent.
  • Your thermostat mounted in the wrong location.
  • The furnace that is too big for your home.

Why does my furnace cycle every 5 minutes?

Blocked Exhaust Vent

This is another cause of a furnace overheating and short cycling. Short cycle time: 1-5 minutes. This issue can be dangerous too, since deadly carbon monoxide is dispersed through the vent. If it is blocked, the gas won't escape, and it can leak out of the furnace and into your home.

Why does my furnace turn on every 10 minutes?

Bad Thermostat : If your thermostat has a problem, it can cause your furnace to run cycles that are either too long or too short. If the thermostat is sensing the incorrect temperature and not sending a cut-off signal soon enough, or if the battery is dying, your thermostat can cause your furnace to run erratically.

Can a bad flame sensor cause short cycling?

Bad Flame Sensor

Flame sensors are also subject to corrosion. This is because your furnace produces small amounts of water during the heating cycle. Over time, this can lead to corrosion and rust in your furnace, resulting in short cycling .

Can short cycling cause a fire?

Since short-cycling is literally the compressor consistently starting up and shutting down more than it needs to, it drains unnecessary power. Your air conditioner's compressor accumulates extensive wear and tear which can cause the system to overheat and burn-out as a result.

Why does my furnace turn on and off every 5 minutes?

Dirty or faulty flame sensor

If your furnace turns off after a few minutes, there is a good chance it is caused by a faulty or dirty flame sensor. This vital component is designed to keep an eye on the gas burner. When it cannot sense that burner, the furnace runs then shuts off and starts again.

Why does my furnace keep shutting off after a few minutes?

If your furnace keeps shutting off, it could be due to low airflow . There are several indirect issues that cause low airflow. Dirty Air Filters. If you don't change your air filters often enough, the filters will become dirty and clogged, which means the heat exchanger retains heat and eventually causes it to overheat.

Why is my heat pump short cycling?

Short cycling occurs when your heat pump automatically shuts off before completing its full heating (or cooling) cycle . This means your system constantly runs in its start-up phase, rather than at its optimal efficiency level. This can cause an increase in energy consumption and a decrease in heating efficiency.

What causes short cycling?

Short-cycling happens when the cooling cycle becomes much shorter than the usual 10 minutes , causing the compressor to turn on and off more often than usual. This excessive stopping and starting adds wear on the compressor while robbing your home of its cooling comfort.

Why does my furnace run every 15 minutes?

The furnace is oversized for your house . It cycles off because an inner safety is getting overheated from inadequate airflow. Either get a smaller furnace or enlarge the duct system to move the amount of air needed by the furnace.

How often should a furnace cycle on and off?

On average, furnaces should kick on and turn off anywhere from three to eight times per hour . However, if your furnace turns on and off more frequently, don't assume the furnace is short cycling just yet.

How often should high efficiency furnace cycle?

On average, furnaces should kick on and off anywhere from 3-8 times per hour . However, if your furnace does so more frequently, don't assume it's short cycling just yet.

Why does my furnace keep cycling on and off?

When gas gets built up in a new furnace it may shut down for extended periods of time until it can be reset to try again . Some older furnaces may not have this and could cycle off and on as gas is built up. This switch turns your furnace off if gases are not properly ventilated out of the exhaust flue.

What can cause the blower to come back on for a short time after cycling off?

When the fan cycles back on while the burner remains off we figure that the heat exchanger is still so hot that even without the burner being on, the air in the plenum heats back up after the fan cuts off , causing the switch to turn the fan back on.